Single phase Auto Switch

Overview

  • Low voltage protection
  • 1 min ON – time delay
  • Auto / manual Switch
  • Suitable for 2 HP submersible Single phase pumps

Technical Specification

Supply voltage 230 VAC , 50Hz ± 5%
Output Relay Contact 1 No
Output Relay Contact for NO volt coil 5 Amp , 240 VAC (Resistive)
Output Relay contact for start capaeitor 30 amp , 240 VAC
Trip time delay for unbalance 2 sec
On time delay 1min (fixed)
Resetting Auto Reset
Enclosure PVC box
Dimension (mm)  
-Dimension (HXWXD) (95 X 144 X 96 mm)
Weight 0.766 gms
Operating condition temperatore -5°C to +55°C

Application